injap mengurangkan standard (dengan injap tiga hala manual) 3 "bebibir (dn80)
Kelebihan:
Injap kawalan hidraulik dengan diafragma induktif tetap di dalam, ditutup atau dibuka oleh kontrol hidraulik.
Jenis Y Direka, Saluran Besar dan pelepasan besar, kehilangan kepala kecil, Kepekaan tindak balas dan Ketepatan tinggi untuk
pelarasan.
Diaphragm induktif fleksibel dan panduan injap teras tetap baik, rintangan kakisan dan tiada ubah bentuk.
Mudah untuk beroperasi sebagai kontrol hidraulik, menyelamatkan usaha untuk menutup atau membuka dan penyelenggaraan mudah.
Dihasilkan oleh bahan plastik bertetulang dengan fungsi hidraulik dan mekanik yang sangat baik, gunakan untuk masa yang lama
Barang No.:
MHV0180FPembayaran:
T/T, L/CAsal Produk:
Xiamen, ChinaWarna:
BlackPelabuhan Pengiriman:
Xiamen
- Maklumat produk
Technical Data:
·Size: 2" (Dn50), 3" (Dn80), 4" (Dn 100).
·Connection: Threaded / Flange.
·Working Pressure : 0.35-10bar (5-145psi).
·Max pressure: 10Bar / 145Psi.
·Highest working temperature: 60 °C.
Application:
Suitable to be installed in Main line or Sub Line to avoid the following drip syestem or mircosprinkler
system to damage by high pressure
Working Pressure : 0.35-10bar (5-145psi).
Pressure Adjusting Range: 0.8-6.5bar (11-95psi).
Connecting Mode: Female Thread/ Clamping /Flange
How to operate:
1. Installed this valve to Pipe line according to the arrow pointed to inlet and outlet. O-Ring should be used if installed with flange.
2. Ensure all connectors & adaptors are well tighten and no leakage. Or should be fixed again
3. Operating:
a. Turn the Three Way Control Valve to "AUTO".
b. Install a Pressure Gauge at the outlet of pressure reducing valve.
c. Loose the Locking Nut at the top of Pilot.
d. Adjust the Screw until the pressure up to requirement.
e. Tighen Locking Nut.
4. For closing Valve, turn the Three Way Control Valve to "CLOSE".
Sebelumnya :
injap terkawal solenoid, 1-1 / 2 ", 3-cara